TOCON Series - UV Sensors with Integrated Amplifier
|
TOCON Series - UV Sensors with Integrated Amplifier |
The TOCON devices are using modern hybrid technology to cancel unwanted signal disturbances caused by moisture or electromagnetic radiation. The output voltage can be directly connected to a controller or a voltage multimeter. No external amplifier is needed. Most of the TOCONs are powered by a Silicon Carbide (SiC) detector chip (ABC, A, B, E, C). The BLUE and GAP series works with a GaP chip. |
|
Key Features |
- SiC based UV hybride detector with pre-amplifier (0 - 5V output)
- measures intensities from 1.8 pW/cm2 up to 18 W/cm2
- UV broadband, UVA, UVB, UVC, Erythema or GaP-blue light measurement
- upgrade to M12x1 housing with Hirschmann connector available
- our product overview allows a simple product selection
|
Step 1: Selection of Spectral Response |
- UV-Broadband (ABC)
- UVA (A)
- UVB (B)
- UVC (C)
- UV-Index(Erythema) (E)
- Blue light (BLUE)
- Galliumphsophid (GaP)
|
Step 2: Selection of Sensitivity Range |
- "1”is very sensitive and“10”is very unsensitive. For detailed specification please refer to Appendix B (page 4) of the datasheet.
|
|
|
TOCON - UV Broadband (SiC) |
Model (Datasheet)
| Approx. min. irradiance
| Approx. max. irradiance (V_supply=15V)
| Applications |
TOCON_ABC1 (flame detection) |
1.8 pW/cm2 |
18 nW/cm2 |
very low UV radiation detection, flame detection. Replaces obsolete UV10.SF and UV10.T2E. |
|
TOCON_ABC2 |
18 pW/cm2 |
180 nW/cm2 |
low UV radiation detection, occupational safety |
|
TOCON_ABC3 |
180 pW/cm2 |
1.8 μW/cm2 |
low UV radiation detection, occupational safety |
|
TOCON_ABC4 |
1.8 nW/cm2 |
18 μW/cm2 |
UV irradiation measurement |
|
TOCON_ABC5 |
18 nW/cm2 |
180 μW/cm2 |
UV irradiation measurement |
|
TOCON_ABC6 |
180 nW/cm2 |
1.8 mW/cm2 |
Optimized for total sun UV measurements (not Erythema curve) |
|
TOCON_ABC7 |
1.8 μW/cm2 |
18 mW/cm2 |
UV irradiation measurement, industrial standard UV radiation |
|
TOCON_ABC8 |
18 μW/cm2 |
180 mW/cm2 |
Curing lamp control |
|
TOCON_ABC9 |
180 μW/cm2 |
1.8 W/cm2 |
Curing lamp control |
|
TOCON_ABC10 |
1.8 mW/cm2 |
18 W/cm2 |
UV hardening control and other very high radiation sources |
|
TOCON - UVA (SiC) *Note: part no. have changed, old part no. until 31 March 2014 |
Model (Datasheet)
| Approx. min. irradiance
| Approx. max. irradiance (V_supply=15V)
| Applications |
TOCON_A4(TOCON_A3) |
1.8 nW/cm2 |
18 μW/cm2 |
UVA radiation detection |
|
TOCON_A5(TOCON_A4) |
18 nW/cm2 |
180 μW/cm2 |
UVA irradiation measurement |
|
TOCON_A6(TOCON_A5) |
180 nW/cm2 |
1.8 mW/cm2 |
UVA irradiation measurement |
|
TOCON_A7(TOCON_A6) |
1.8 μW/cm2 |
18 mW/cm2 |
UVA irradiation measurement |
|
TOCON_A8(TOCON_A7) |
18 μW/cm2 |
180 mW/cm2 |
Measurement of high UVA irradiation, curing lamp control |
|
TOCON_A9(TOCON_A8) |
180 μW/cm2 |
1.8 W/cm2 |
Measurement of very high UVA irradiation, curing lamp control |
|
TOCON_A10(TOCON_A9) |
1.8 mW/cm2 |
18 W/cm2 |
Measurement of very high UVA irradiation, curing lamp control |
|
TOCON - UVB (SiC) *Note: part no. have changed, old part no. until 31 March 2014 |
Model (Datasheet)
| Approx. max. irradiance
| Applications |
TOCON_B4(TOCON_B1) |
7.5 μW/cm2 |
UVB irradiation measurement |
|
TOCON_B5(TOCON_B2) |
75 μW/cm2 |
UVB irradiation measurement |
|
TOCON_B6(TOCON_B3) |
0.75 mW/cm2 |
UVB irradiation measurement |
|
TOCON - UVC (SiC) |
Model (Datasheet)
| Approx. min. irradiance
| Approx. max. irradiance (V_supply=15V)
| Applications |
TOCON_C2 |
18 pW/cm2 |
180 nW/cm2 |
low UVC radiation detection, occupational safety |
|
TOCON_C3 |
180 pW/cm2 |
1.8 μW/cm2 |
UVC radiation detection, occupational safety |
|
TOCON_C4 |
1.8 nW/cm2 |
18 μW/cm2 |
UVC irradiation measurement |
|
TOCON_C5 |
18 nW/cm2 |
180 μW/cm2 |
Purification lamp control |
|
TOCON_C6 |
180 nW/cm2 |
1.8 mW/cm2 |
Purification lamp control |
|
TOCON_C7 |
1.8 μW/cm2 |
18 mW/cm2 |
Purification lamp control |
|
TOCON_C8 |
18 μW/cm2 |
180 mW/cm2 |
Curing lamp control |
|
TOCON_C9 |
180 μW/cm2 |
1.8 W/cm2 |
Curing lamp control |
|
TOCON - UV-Index (Erythema) (SiC) |
Model (Datasheet)
| Approx. max. irradiance
| Applications |
TOCON_E1 |
3 UVI |
UV-Index measurements (this device needs sunlight attenuator) |
|
TOCON_E2 |
30 UVI |
UV-Index measurements |
|
TOCON - Blue Light (GaP) *Note: part no. have changed, old part no. until 31 March 2014 |
Model (Datasheet)
| Approx. min. irradiance
| Approx. max. irradiance (V_supply=15V)
| Applications |
TOCON_blue4(TOCON_blue1) |
4.2 nW/cm2 |
43 μW/cm2 |
Measurement of very low blue light irradiation, occupational safety |
|
TOCON_blue5(TOCON_blue2) |
42 nW/cm2 |
430 μW/cm2 |
Measurement of low blue light irradiation, occupational safety |
|
TOCON_blue6(TOCON_blue3) |
420 nW/cm2 |
4.3 mW/cm2 |
Measurement of blue light irradiation, occupational safety |
|
TOCON_blue7(TOCON_blue4) |
4.2 μW/cm2 |
43 mW/cm2 |
Measurement of blue light irradiation, occupational safety |
|
TOCON_blue8(TOCON_blue5) |
42 μW/cm2 |
430 mW/cm2 |
Measurement of high blue light irradiation, occupational safety |
|
TOCON_blue9(TOCON_blue6) |
420 μW/cm2 |
4.3 W/cm2 |
Measurement of very high blue light irradiation, occupational safety |
|
TOCON - UV+VIS (GaP) *Note: part no. have changed, old part no. until 31 March 2014 |
Model (Datasheet)
| Approx. min. irradiance
| Approx. max. irradiance (V_supply=15V)
| Applications |
TOCON_GaP4(TOCON_GaP1) |
4.2 nW/cm2 |
43 μW/cm2 |
Measurement of very low UV & VIS light irradiation, occupational safety |
|
TOCON_GaP5(TOCON_GaP2) |
42 nW/cm2 |
430 μW/cm2 |
Measurement of low UV & VIS light irradiation, occupational safety |
|
TOCON_GaP6(TOCON_GaP3) |
420 nW/cm2 |
4.3 mW/cm2 |
Measurement of UV & VIS light irradiation, occupational safety |
|
TOCON_GaP7(TOCON_GaP4) |
4.2 μW/cm2 |
43 mW/cm2 |
Measurement of UV & VIS light irradiation, occupational safety |
|
TOCON_GaP8(TOCON_GaP5) |
42 μW/cm2 |
430 mW/cm2 |
Measurement of high UV & VIS light irradiation, occupational safety |
|
TOCON_GaP9(TOCON_GaP6) |
420 μW/cm2 |
4.3 W/cm2 |
Measurement of very high UV & VIS light irradiation, occupational safety |
|
TOCON Housing (Optional) |
Model (Datasheet)
| Properties |
TOCON_steel_housing |
M12x1 thread, 32 mm length, integrated sensor connector, price incl. 2 m plug cable. |
|
TOCON_PTFE_housing |
M12x1 thread, material teflon (PTFE), 31 mm length, integrated sensor connector, price incl. 2 m plug cable. |
|
TOCON_starter_kit |
Kit for initial testing setup, includes a TOCON socket, two banana plugs to connecct with a voltmeter and a 9V block battery |
|
|
|
|
|
|
|
|
Address:4F-3. No.171. Sec.2. Chang An.E.Rd. Taipei. Taiwan. R.O.C. |
Tel:886-2-27111093~5 |
Fax:886-2-27310902 |
|
|
|
駿融企業有限公司 版權所有 © 2012 JIN ZON ENTERPRISE CO., LTD. All Rights Reserved.
TEL:886-2-2711-1093~5 FAX:886-2-2731-0902
183403
|
| |